Large power plants feed their electricity into this level and distribute it to the subordinate distribution grids, from which the electricity goes to households. In addition, the transmission grid connects the German electricity grid with those of neighbouring European countries and the European energy exchange.
A strong and highly interconnected electricity grid is one of the key flexibility assets in Germany – and Europe. No other region of the world has a comparable cross-national grid as robust, reliable and interconnected as that in Europe.
Being responsible for Germany's high-voltage grid, TSOs maintain, operate, plan and expand grid infrastructure. For example, 50Hertz Transmission — owned by Belgian company Elia Group (80%) and German state-owned KfW banking group (20%) — controls the grid in eastern Germany and parts of it in the north.
In Germany the high voltage transmission grid is largely owned by the four transmission system operators (TSOs): TenneT, 50Hertz Transmission, Amprion and TransnetBW. At the level of the distribution grids the electricity is transmitted at high, medium and low voltage. The high voltage grid is used for the primary distribution of the electricity.
Some BESS suppliers mandate uninterrupted power to maintain the operation of thermal management systems, ensuring battery temperatures remain within desired limits to minimize degradation. BESS fire safety standards, such as NFPA 855, outline minimum requirements for backup power for fire safety systems.
For certain projects, backup power must be provided for the BESS auxiliary load as required by the BESS supplier or fire codes. Some BESS suppliers mandate uninterrupted power to maintain the operation of thermal management systems, ensuring battery temperatures remain within desired limits to minimize degradation.
Project owners are also responsible for the electricity costs associated with the BESS auxiliary load during operation. The electricity cost for auxiliary loads depends on the energy consumption (kWh) and the pricing structure set by independent system operators or utilities. For example:
BESS auxiliary loads typically fall into the following three categories: ● Control and communication equipment, such as the battery management system and network switches; ● Thermal management systems, such as HVAC or chillers; ● Fire safety systems, such as fire alarms, control panels and gas ventilation systems (if present).
For certain projects, backup power must be provided for the BESS auxiliary load as required by the BESS supplier or fire codes. Some BESS suppliers mandate uninterrupted power to maintain the operation of thermal management systems, ensuring battery temperatures remain within desired limits to minimize degradation.
Project owners are also responsible for the electricity costs associated with the BESS auxiliary load during operation. The electricity cost for auxiliary loads depends on the energy consumption (kWh) and the pricing structure set by independent system operators or utilities. For example:
Some BESS suppliers mandate uninterrupted power to maintain the operation of thermal management systems, ensuring battery temperatures remain within desired limits to minimize degradation. BESS fire safety standards, such as NFPA 855, outline minimum requirements for backup power for fire safety systems.
If a BESS product cannot meet these backup power requirements as mandated by the code or the Authority Having Jurisdiction (AHJ), an external backup power source needs to be provided. Options for backup power include local distribution network feeders (if available with sufficient kVA rating) or backup generators.